[email protected] |
![]() |
3275638434 |
![]() |
![]() |
Paper Publishing WeChat |
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
LOKIBASE: The Device for Seismic Isolation of Pallet Racking Systems—Optimization Analysis
Marco Ferrari
Full-Text PDF
XML 37 Views
DOI:10.17265/1934-7359/2025.08.001
Girardini Srl, Tione di Trento (TN), 38079, Italy
LOKIBASE is a non-linear isolator/dissipator device to protect pallet racking systems against the earthquake. LOKIBASE consists of the following main components: (1) two slider devices on which a rubber membrane is set up (LOKI devices). LOKI devices are linear displacement dependent ones; (2) a cylindrical beam damper (“CANDLE” device). The “CANDLE” device is a non-linear displacement dependent one; (3) two anti-lifting devices (“UP-LIFT” devices); (4) a fuse plug (see www.lokibasedevice.com). The main work which is the purpose of the paper, is the optimization of the behavior of an isolator/dissipator device to mitigate the seismic action on special structures, where the stiffness values are very different in the main cross-aisle and down-aisle directions. Under seismic action, in these structures it is very important to reduce the value of the forces at the Limit state for the safeguard of human life (SLV) in the down-aisle direction as much as possible and simultaneously to use the highest damping value allowed by the building rules to reduce the LOKIBASE displacement at the Limit state for collapse prevention (SLC) in the cross-aisle direction. The goal was achieved through a cylindrical device made of stainless steel (AISI304) with an optimized shape, under large displacement during seismic action.
LOKIBASE, “CANDLE”, pallet racking systems, cylindrical beam damper, holed cylindrical beam damper.
Journal of Civil Engineering and Architecture 19 (2025) 361-372
doi: 10.17265/1934-7359/2025.08.001
[1] Technical and Commercial LOKIBASE. 2025. www.lokibasedevice.com. (in Italian and English)
[2] NTC. 2018. Norme tecniche per le costruzioni, DM 17 gennaio 2018, published in the Gazzetta Ufficiale n.42 of 20 February 2018—Suppl. Ordinario n.8—Italian Code. Roma: NTC. (in Italian)
[3] Castiglioni, C., and Quaglini, V. 2010. “Linea Guida per il rilascio dell’Attestato di Qualificazione per Isolatori Antisismici per Scaffalature Industriali BASE GFMI.” (in Italian)
[4] Castiglioni, C., and Quaglini, V. 2010. “Rapporto di Valutazione per Isolatori Antisismici per Scaffalature Industriali BASE GFMI.” (in Italian)
[5] Zandonini, R., and Molinari, M. 2015. “Certificato di prova n°LPMS 045/2015—Prova di barre d’acciaio inox diam.16mm a trazione, a flessione monotona e ciclica a frequenza 0.5 Hz in un vincolo metallico e inghisate con resina in calcestruzzo.” (in Italian)
[6] Camporesi, G., and Ceroni, P. 2014. “Relazione di verifica delle performance e specifiche del dispositivo antisismico per scaffalature tipo LOKI.” (in Italian)
[7] Ferrari, M. 2019. “Costruzioni metalliche n°3—LOKIBASE (1st Part): The Device for Seismic Isolation of Pallet Racking Systems.” (in Italian)
[8] Ferrari, M. 2019. “Costruzioni metalliche n°4—LOKIBASE (2nd part): The Device for Seismic Isolation of Pallet Racking Systems.” (in Italian)
[9] Ferrari, M. 2019. “LOKIBASE—The Device for Seismic Isolation of Pallet Racking Systems—Optimization Analysis.” In Proceedings of the CTA (Congress of Technicians of Steel), 3-5 October 2019, Bologna, Italy.
[10] Ferrari, M. 2024. “LOKIBASE—The Device for Seismic Isolation of Pallet Racking Systems—Optimization Analysis.” In Proceedings of the 18th World Conference on Earthquake Engineering WCEE, 30 June-5 July 2024, Milan, Italy.