ABSTRACT
System control and safety reliability are important links of the marine DC (Direct Current) power system. The
simulation model is built by Matlab/Simulink, the battery and super-capacitor are
supplied to the system through a three-phase interleaved DC/DC converter, the fuse and disconnector switch
combination are used as the protection device, and the short-circuit point is
set between each branch and the DC distribution board, performing short-circuit
simulation. This paper also proposes a short-circuit calculation method for super-capacitors based
on the simplified model of series RC (Resistors & Capacitors), and verifies
its correctness through simulation data. The results show that the introduction of a three-phase interleaved
DC/DC converter reduces the current ripple and makes the system control more
convenient; short-circuit
calculation and simulation have determined the short-circuit withstand
capability of the DC distribution board, and verified the feasibility of the fuse selection method
and the short-circuit calculation method of the super-capacitor. This provides
reliable verification for the application and calculation of the actual
project.
KEYWORDS
Matlab/simulink simulation, three-phase
interleaved DC/DC, battery and super-capacitor, short-circuit
protection and calculation.